OpenPlant Modeler Help

To Place Megalug Flange Adapter Using Autofitting

Define configuration variable OPM_PREFER_MEGALUG =1 to enable MegaLug joints.
To place Mega lug flange using auto-fitting , follow these steps:
  1. Place a pipe of desired length.
  2. Select the Flange option from the Piping Galleries.

    In the Component Center, the list of available flanges appears.

  3. Select the Weldneck flange and continue to place it from the end of the pipe.

    The flange adapter gets placed automatically.